Monish S Raut, Arun Maheshwari, Sumir Dubey, Ganesh Shivnani, Sandeep Joshi, Arvind Verma, Swetanka Das

Annals of Cardiac Anaesthesia 2017 20(3):333-334

Malposition of venous cannula can cause inadequate venous drainage during cardiopulmonary bypass. It would be good clinical practice to use TEE to check the position of inferior venous cannula to avoid this problem at the earliest.